Filtered by vendor Tenda Subscriptions
Total 1734 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2026-27514 1 Tenda 2 F3, F3 Firmware 2026-03-05 6.5 Medium
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data.
CVE-2026-27513 1 Tenda 2 F3, F3 Firmware 2026-03-05 4.3 Medium
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a cross-site request forgery (CSRF) vulnerability in the web-based administrative interface. The interface does not implement anti-CSRF protections, allowing an attacker to induce an authenticated administrator to submit state-changing requests, which can result in unauthorized configuration changes.
CVE-2026-27512 1 Tenda 2 F3, F3 Firmware 2026-03-05 6.1 Medium
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response body. Under affected browser behaviors, MIME sniffing may cause the response to be interpreted as active HTML, enabling script execution in the context of the administrative interface.
CVE-2026-27511 1 Tenda 2 F3, F3 Firmware 2026-03-05 4.3 Medium
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and trick an authenticated administrator into unintended interactions that may result in unauthorized configuration changes.
CVE-2026-25857 1 Tenda 2 G300-f, Rx9 Pro Firmware 2026-03-05 N/A
Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.
CVE-2026-24441 1 Tenda 2 Ac7, Ac7 Firmware 2026-03-05 5.9 Medium
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
CVE-2026-24440 1 Tenda 2 W30e, W30e Firmware 2026-03-05 8.8 High
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained.
CVE-2026-24439 1 Tenda 2 W30e, W30e Firmware 2026-03-05 6.5 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) fail to include the X-Content-Type-Options: nosniff response header on web management interfaces. As a result, browsers that perform MIME sniffing may incorrectly interpret attacker-influenced responses as executable script.
CVE-2026-24437 1 Tenda 2 W30e, W30e Firmware 2026-03-05 5.5 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) serve sensitive administrative content without appropriate cache-control directives. As a result, browsers may store credential-bearing responses locally, exposing them to subsequent unauthorized access.
CVE-2026-24436 1 Tenda 2 W30e, W30e Firmware 2026-03-05 9.8 Critical
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) do not enforce rate limiting or account lockout mechanisms on authentication endpoints. This allows attackers to perform unrestricted brute-force attempts against administrative credentials.
CVE-2026-24435 1 Tenda 2 W30e, W30e Firmware 2026-03-05 6.5 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) implement an insecure Cross-Origin Resource Sharing (CORS) policy on authenticated administrative endpoints. The device sets Access-Control-Allow-Origin: * in combination with Access-Control-Allow-Credentials: true, allowing attacker-controlled origins to issue credentialed cross-origin requests.
CVE-2026-24434 1 Tenda 2 Ac7, Ac7 Firmware 2026-03-05 6.5 Medium
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
CVE-2026-24433 1 Tenda 2 W30e, W30e Firmware 2026-03-05 5.4 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages.
CVE-2026-24432 1 Tenda 2 W30e, W30e Firmware 2026-03-05 4.3 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) lack cross-site request forgery (CSRF) protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered by an authenticated user’s browser, modify administrative passwords and other configuration settings.
CVE-2026-24431 1 Tenda 2 W30e, W30e Firmware 2026-03-05 6.5 Medium
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) display stored user account passwords in plaintext within the administrative web interface. Any user with access to the affected management pages can directly view credentials.
CVE-2026-24430 1 Tenda 2 W30e, W30e Firmware 2026-03-05 7.5 High
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) disclose sensitive account credentials in cleartext within HTTP responses generated by the maintenance interface. Because the management interface is accessible over unencrypted HTTP by default, credentials may be exposed to network-based interception.
CVE-2026-24429 1 Tenda 2 W30e, W30e Firmware 2026-03-05 9.8 Critical
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface.
CVE-2026-24428 1 Tenda 2 W30e, W30e Firmware 2026-03-05 8.8 High
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain an authorization flaw in the user management API that allows a low-privileged authenticated user to change the administrator account password. By sending a crafted request directly to the backend endpoint, an attacker can bypass role-based restrictions enforced by the web interface and obtain full administrative privileges.
CVE-2026-24427 1 Tenda 2 Ac7, Ac7 Firmware 2026-03-05 5.5 Medium
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.
CVE-2026-24426 1 Tenda 2 Ac7, Ac7 Firmware 2026-03-05 6.1 Medium
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.