Total
842 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-69969 | 1 Powertech | 1 Pebble Prism Ultra | 2026-03-05 | 9.6 Critical |
| A lack of authentication and authorization mechanisms in the Bluetooth Low Energy (BLE) communication protocol of SRK Powertech Pvt Ltd Pebble Prism Ultra v2.9.2 allows attackers to reverse engineer the protocol and execute arbitrary commands on the device without establishing a connection. This is exploitable over Bluetooth Low Energy (BLE) proximity (Adjacent), requiring no physical contact with the device. Furthermore, the vulnerability is not limited to arbitrary commands but includes cleartext data interception and unauthenticated firmware hijacking via OTA services. | ||||
| CVE-2026-24441 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2026-03-05 | 5.9 Medium |
| Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material. | ||||
| CVE-2026-20801 | 2026-03-03 | 5.6 Medium | ||
| Cleartext Transmission of Sensitive Information (CWE-319) in a component used in the Gallagher Hanwha VMS and Gallagher NxWitness VMS integrations allows unprivileged users with local network access to view live video streams. This issue affects all versions of Gallagher NxWitness VMS integration prior to 9.10.017 and Gallagher Hanwha VMS integration prior to 9.10.025. | ||||
| CVE-2026-27752 | 3 Shenzhen Hongyavision Technology Co, Sodola-network, Sodolanetworks | 4 Sodola Sl902-swtgw124as, Sl902-swtgw124as, Sl902-swtgw124as Firmware and 1 more | 2026-03-03 | 5.9 Medium |
| SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 transmit authentication credentials over unencrypted HTTP, allowing attackers to capture credentials. An attacker positioned to observe network traffic between a user and the device can intercept credentials and reuse them to gain administrative access to the gateway. | ||||
| CVE-2024-43766 | 1 Google | 1 Android | 2026-03-03 | 6.5 Medium |
| In multiple functions of btm_ble_sec.cc, there is a possible unencrypted communication due to Invalid error handling. This could lead to remote (proximal/adjacent) information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
| CVE-2025-58107 | 1 Microsoft | 4 Exchange, Exchange Server, Exchange Server 2016 and 1 more | 2026-03-03 | 7.5 High |
| In Microsoft Exchange through 2019, Exchange ActiveSync (EAS) configurations on on-premises servers may transmit sensitive data from Samsung mobile devices in cleartext, including the user's name, e-mail address, device ID, bearer token, and base64-encoded password. | ||||
| CVE-2025-26654 | 2026-02-26 | 6.8 Medium | ||
| SAP Commerce Cloud (Public Cloud) does not allow to disable unencrypted HTTP (port 80) entirely, but instead allows a redirect from port 80 to 443 (HTTPS). As a result, Commerce normally communicates securely over HTTPS. However, the confidentiality and integrity of data sent on the first request before the redirect may be impacted if the client is configured to use HTTP and sends confidential data on the first request before the redirect. | ||||
| CVE-2025-27903 | 1 Ibm | 2 Db2 Recovery Expert, Db2 Recovery Expert For Luw | 2026-02-26 | 5.9 Medium |
| IBM DB2 Recovery Expert for LUW 5.5 Interim Fix 002 IBM Db2 Recovery Expert for Linux, UNIX and Windows transmits data in a cleartext communication channel that could allow an attacker to obtain sensitive information using man in the middle techniques. | ||||
| CVE-2025-53139 | 1 Microsoft | 17 Windows, Windows 10, Windows 10 21h2 and 14 more | 2026-02-26 | 7.7 High |
| Cleartext transmission of sensitive information in Windows Hello allows an unauthorized attacker to bypass a security feature locally. | ||||
| CVE-2025-11492 | 1 Connectwise | 1 Automate | 2026-02-26 | 9.6 Critical |
| In the ConnectWise Automate Agent, communications could be configured to use HTTP instead of HTTPS. In such cases, an on-path threat actor with a man-in-the-middle network position could intercept, modify, or replay agent-server traffic. Additionally, the encryption method used to obfuscate some communications over the HTTP channel is updated in the Automate 2025.9 patch to enforce HTTPS for all agent communications. | ||||
| CVE-2026-22271 | 1 Dell | 3 Ecs Streamer, Elastic Cloud Storage, Objectscale | 2026-02-26 | 7.5 High |
| Dell ECS, versions 3.8.1.0 through 3.8.1.7, and Dell ObjectScale versions prior to 4.2.0.0, contains a Cleartext Transmission of Sensitive Information vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to information exposure. | ||||
| CVE-2025-13454 | 1 Lenovo | 8 Thinkplus Fu100, Thinkplus Fu100 Firmware, Thinkplus Fu200 and 5 more | 2026-02-25 | 5.5 Medium |
| A potential vulnerability was reported in ThinkPlus configuration software that could allow a local authenticated user to gain access to sensitive device information. | ||||
| CVE-2024-1657 | 1 Redhat | 3 Ansible Automation Platform, Ansible Automation Platform Developer, Ansible Automation Platform Inside | 2026-02-25 | 8.1 High |
| A flaw was found in the ansible automation platform. An insecure WebSocket connection was being used in installation from the Ansible rulebook EDA server. An attacker that has access to any machine in the CIDR block could download all rulebook data from the WebSocket, resulting in loss of confidentiality and integrity of the system. | ||||
| CVE-2023-23841 | 1 Solarwinds | 1 Serv-u | 2026-02-25 | 7.5 High |
| SolarWinds Serv-U is submitting an HTTP request when changing or updating the attributes for File Share or File request. Part of the URL of the request discloses sensitive data. | ||||
| CVE-2023-50703 | 1 Efacec | 2 Uc 500e, Uc 500e Firmware | 2026-02-25 | 6.3 Medium |
| An attacker with network access could perform a man-in-the-middle (MitM) attack and capture sensitive information to gain unauthorized access to the application. | ||||
| CVE-2024-38891 | 1 Horizoncloud | 1 Caterease | 2026-02-24 | 9.1 Critical |
| An issue in Horizon Business Services Inc. Caterease 16.0.1.1663 through 24.0.1.2405 and possibly later versions, allows a remote attacker to perform a Sniffing Network Traffic attack due to the cleartext transmission of sensitive information. | ||||
| CVE-2024-5462 | 1 Broadcom | 1 Fabric Operating System | 2026-02-23 | 7.5 High |
| If Brocade Fabric OS before Fabric OS 9.2.0 configuration settings are not set to encrypt SNMP passwords, then the SNMP privsecret / authsecret fields can be exposed in plaintext. The plaintext passwords can be exposed in a configupload capture or a supportsave capture if encryption of passwords is not enabled. An attacker can use these passwords to fetch values of the supported OIDs via SNMPv3 queries. There are also a limited number of MIB objects that can be modified. | ||||
| CVE-2026-24455 | 1 Jinan Usr Iot Technology Limited (pusr) | 1 Usr-w610 | 2026-02-23 | 7.5 High |
| The embedded web interface of the device does not support HTTPS/TLS for authentication and uses HTTP Basic Authentication. Traffic is encoded but not encrypted, exposing user credentials to passive interception by attackers on the same network. | ||||
| CVE-2025-55248 | 4 Apple, Linux, Microsoft and 1 more | 22 Macos, Linux Kernel, .net and 19 more | 2026-02-22 | 4.8 Medium |
| Inadequate encryption strength in .NET, .NET Framework, Visual Studio allows an authorized attacker to disclose information over a network. | ||||
| CVE-2019-25278 | 1 Iwt | 2 Facesentry Access Control System, Facesentry Access Control System Firmware | 2026-02-18 | 5.9 Medium |
| FaceSentry Access Control System 6.4.8 contains a cleartext transmission vulnerability that allows remote attackers to intercept authentication credentials. Attackers can perform man-in-the-middle attacks to capture HTTP cookie authentication information during network communication. | ||||