Search Results (1739 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-27739 1 Angular 3 @nguniversal/common, @nguniversal/express-engine, Angular 2026-02-27 N/A
The Angular SSR is a server-rise rendering tool for Angular applications. Versions prior to 21.2.0-rc.1, 21.1.5, 20.3.17, and 19.2.21 have a Server-Side Request Forgery (SSRF) vulnerability in the Angular SSR request handling pipeline. The vulnerability exists because Angular’s internal URL reconstruction logic directly trusts and consumes user-controlled HTTP headers specifically the Host and `X-Forwarded-*` family to determine the application's base origin without any validation of the destination domain. Specifically, the framework didn't have checks for the host domain, path and character sanitization, and port validation. This vulnerability manifests in two primary ways: implicit relative URL resolution and explicit manual construction. When successfully exploited, this vulnerability allows for arbitrary internal request steering. This can lead to credential exfiltration, internal network probing, and a confidentiality breach. In order to be vulnerable, the victim application must use Angular SSR (Server-Side Rendering), the application must perform `HttpClient` requests using relative URLs OR manually construct URLs using the unvalidated `Host` / `X-Forwarded-*` headers using the `REQUEST` object, the application server must be reachable by an attacker who can influence these headers without strict validation from a front-facing proxy, and the infrastructure (Cloud, CDN, or Load Balancer) must not sanitize or validate incoming headers. Versions 21.2.0-rc.1, 21.1.5, 20.3.17, and 19.2.21 contain a patch. Some workarounds are available. Avoid using `req.headers` for URL construction. Instead, use trusted variables for base API paths. Those who cannot upgrade immediately should implement a middleware in their `server.ts` to enforce numeric ports and validated hostnames.
CVE-2026-25785 1 Motex 1 Lanscope Endpoint Manager 2026-02-27 N/A
Path traversal vulnerability exists in Lanscope Endpoint Manager (On-Premises) Sub-Manager Server Ver.9.4.7.3 and earlier, which may allow an attacker to tamper with arbitrary files and execute arbitrary code on the affected system.
CVE-2026-23518 1 Fleetdm 1 Fleet 2026-02-27 9.8 Critical
Fleet is open source device management software. In versions prior to 4.78.3, 4.77.1, 4.76.2, 4.75.2, and 4.53.3, a vulnerability in Fleet's Windows MDM enrollment flow could allow an attacker to submit forged authentication tokens that are not properly validated. Because JWT signatures were not verified, Fleet could accept attacker-controlled identity claims, enabling enrollment of unauthorized devices under arbitrary Azure AD user identities. Versions 4.78.3, 4.77.1, 4.76.2, 4.75.2, and 4.53.3 fix the issue. If an immediate upgrade is not possible, affected Fleet users should temporarily disable Windows MDM.
CVE-2019-25362 2 Allok Soft, Alloksoft 2 Wmv To Avi Mpeg Dvd Wmv Convertor, Wmv To Avi Mpeg Dvd Wmv Convertor 2026-02-27 9.8 Critical
WMV to AVI MPEG DVD WMV Convertor 4.6.1217 contains a buffer overflow vulnerability that allows attackers to execute arbitrary code by overwriting the license name and license code fields. Attackers can craft a malicious payload of 6000 bytes to trigger a bind shell on port 4444 by exploiting a stack-based buffer overflow in the application's input handling.
CVE-2025-1242 1 Gardyn 3 Home Kit, Home Kit Cloud Api, Home Kit Mobile Application 2026-02-27 9.1 Critical
The administrative credentials can be extracted through application API responses, mobile application reverse engineering, and device firmware reverse engineering. The exposure may result in an attacker gaining full administrative access to the Gardyn IoT Hub exposing connected devices to malicious control.
CVE-2026-0542 1 Servicenow 1 Servicenow Ai Platform 2026-02-27 N/A
ServiceNow has addressed a remote code execution vulnerability that was identified in the ServiceNow AI platform. This vulnerability could enable an unauthenticated user, in certain circumstances, to execute code within the ServiceNow Sandbox.    ServiceNow addressed this vulnerability by deploying a security update to hosted instances. Relevant security updates also have been provided to ServiceNow self-hosted customers and partners. Further, the vulnerability is addressed in the listed patches and hot fixes. While we are not currently aware of exploitation against customer instances, we recommend customers promptly apply appropriate updates or upgrade if they have not already done so.
CVE-2026-1610 1 Tenda 3 Ax12 Pro, Ax12 Pro Firmware, Ax2 Pro 2026-02-27 8.1 High
A vulnerability was found in Tenda AX12 Pro V2 16.03.49.24_cn. Affected by this issue is some unknown functionality of the component Telnet Service. Performing a manipulation results in hard-coded credentials. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The exploit has been made public and could be used.
CVE-2026-22553 1 Insat 2 Masterscada, Masterscada Buk-ts 2026-02-27 9.8 Critical
All versions of InSAT MasterSCADA BUK-TS are susceptible to OS command injection through a field in its MMadmServ web interface. Malicious users that use the vulnerable endpoint are potentially able to cause remote code execution.
CVE-2026-21410 1 Insat 2 Masterscada, Masterscada Buk-ts 2026-02-27 9.8 Critical
InSAT MasterSCADA BUK-TS is susceptible to SQL Injection through its main web interface. Malicious users that use the vulnerable endpoint are potentially able to cause remote code execution.
CVE-2026-2333 2 Owl, Owlcyberdefense 4 Opds, Opds-100, Opds-1000 and 1 more 2026-02-26 9.8 Critical
Improper Neutralization of Special Elements used in a Command ('Command Injection') in Owl opds 2.2.0.4 allows Command Injection via a crafted network request.
CVE-2026-26333 1 Calero 1 Verasmart 2026-02-26 9.8 Critical
Calero VeraSMART versions prior to 2022 R1 expose an unauthenticated .NET Remoting HTTP service on TCP port 8001. The service publishes default ObjectURIs (including EndeavorServer.rem and RemoteFileReceiver.rem) and permits the use of SOAP and binary formatters with TypeFilterLevel set to Full. An unauthenticated remote attacker can invoke the exposed remoting endpoints to perform arbitrary file read and write operations via the WebClient class. This allows retrieval of sensitive files such as WebRoot\\web.config, which may disclose IIS machineKey validation and decryption keys. An attacker can use these keys to generate a malicious ASP.NET ViewState payload and achieve remote code execution within the IIS application context. Additionally, supplying a UNC path can trigger outbound SMB authentication from the service account, potentially exposing NTLMv2 hashes for relay or offline cracking.
CVE-2026-26335 1 Calero 1 Verasmart 2026-02-26 9.8 Critical
Calero VeraSMART versions prior to 2022 R1 use static ASP.NET/IIS machineKey values configured for the VeraSMART web application and stored in C:\\Program Files (x86)\\Veramark\\VeraSMART\\WebRoot\\web.config. An attacker who obtains these keys can craft a valid ASP.NET ViewState payload that passes integrity validation and is accepted by the application, resulting in server-side deserialization and remote code execution in the context of the IIS application.
CVE-2026-26366 2 Jung, Jung-group 2 Enet Smart Home Server, Enet Smart Home 2026-02-26 9.8 Critical
eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and commissioning without enforcing a mandatory password change. Unauthenticated attackers can use these default credentials to gain administrative access to sensitive smart home configuration and control functions.
CVE-2026-22785 2 Orval, Orval-labs 2 Orval, Orval 2026-02-26 9.8 Critical
orval generates type-safe JS clients (TypeScript) from any valid OpenAPI v3 or Swagger v2 specification. Prior to 7.18.0, the MCP server generation logic relies on string manipulation that incorporates the summary field from the OpenAPI specification without proper validation or escaping. This allows an attacker to "break out" of the string literal and inject arbitrary code. This vulnerability is fixed in 7.18.0.
CVE-2025-64121 2 Nuvation Energy, Nuvationenergy 6 Multi-stack Controller, Nplatform, Nuvmsc3-04s-c and 3 more 2026-02-26 9.8 Critical
Authentication Bypass Using an Alternate Path or Channel vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows Authentication Bypass.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
CVE-2025-64120 2 Nuvation Energy, Nuvationenergy 6 Multi-stack Controller, Nplatform, Nuvmsc3-04s-c and 3 more 2026-02-26 8.8 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Nuvation Energy Multi-Stack Controller (MSC) allows OS Command Injection.This issue affects Multi-Stack Controller (MSC): from 2.3.8 before 2.5.1.
CVE-2024-54085 2 Ami, Netapp 19 Megarac Sp-x, H300s, H300s Firmware and 16 more 2026-02-26 9.8 Critical
AMI’s SPx contains a vulnerability in the BMC where an Attacker may bypass authentication remotely through the Redfish Host Interface. A successful exploitation of this vulnerability may lead to a loss of confidentiality, integrity, and/or availability.
CVE-2025-30065 1 Apache 2 Parquet, Parquet Java 2026-02-26 9.8 Critical
Schema parsing in the parquet-avro module of Apache Parquet 1.15.0 and previous versions allows bad actors to execute arbitrary code Users are recommended to upgrade to version 1.15.1, which fixes the issue.
CVE-2024-11235 2 Php, Redhat 2 Php, Enterprise Linux 2026-02-26 8.1 High
In PHP versions 8.3.* before 8.3.19 and 8.4.* before 8.4.5, a code sequence involving __set handler or ??=  operator and exceptions can lead to a use-after-free vulnerability. If the third party can control the memory layout leading to this, for example by supplying specially crafted inputs to the script, it could lead to remote code execution.
CVE-2025-36546 1 F5 2 F5os-a, F5os-c 2026-02-26 8.1 High
On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is still allowed. For an attacker to exploit this vulnerability they must obtain the root user's SSH private key.   Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.