| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-6032 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2025-04-20 | N/A |
| A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks. | ||||
| CVE-2017-5157 | 2 Schneider-electric, Schneider Electric | 2 Homelynk Controller Lss100100, Homelynk Controller Lss100100 Firmware | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. | ||||
| CVE-2016-8374 | 1 Schneider-electric | 16 Magelis Gto Advanced Optimum Panel, Magelis Gto Advanced Optimum Panel Firmware, Magelis Gtu Universal Panel and 13 more | 2025-04-20 | 7.5 High |
| An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION. | ||||
| CVE-2017-6019 | 1 Schneider-electric | 2 Conext Combox 865-1058, Conext Combox 865-1058 Firmware | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot. | ||||
| CVE-2017-6034 | 1 Schneider-electric | 2 Modbus, Modbus Firmware | 2025-04-20 | N/A |
| An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. | ||||
| CVE-2016-8354 | 1 Schneider-electric | 1 Unity Pro | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions. | ||||
| CVE-2016-8352 | 1 Schneider-electric | 6 Connexium Firmware, Tcsefec23f3f20, Tcsefec23f3f21 and 3 more | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code. | ||||
| CVE-2017-9631 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2025-04-20 | 7.5 High |
| A Null Pointer Dereference issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The null pointer dereference vulnerability could allow an attacker to crash the logger process, causing a denial of service for logging and log-viewing (applications that use the Wonderware ArchestrA Logger continue to run when the Wonderware ArchestrA Logger service is unavailable). | ||||
| CVE-2017-6017 | 1 Schneider-electric | 30 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 27 more | 2025-04-20 | N/A |
| A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. | ||||
| CVE-2017-6026 | 1 Schneider-electric | 4 Modicon M241, Modicon M241 Firmware, Modicon M251 and 1 more | 2025-04-20 | 9.1 Critical |
| A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised. | ||||
| CVE-2017-9957 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials. | ||||
| CVE-2017-9958 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root. | ||||
| CVE-2017-9959 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. | ||||
| CVE-2017-9960 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user. | ||||
| CVE-2017-9627 | 1 Schneider-electric | 1 Wonderware Archestra Logger | 2025-04-20 | 8.6 High |
| An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service. | ||||
| CVE-2017-8371 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2025-04-20 | N/A |
| Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors. | ||||
| CVE-2017-7972 | 1 Schneider-electric | 3 Citect Anywhere, Powerscada Anywhere, Powerscada Expert | 2025-04-20 | N/A |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes. | ||||
| CVE-2017-7973 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database. | ||||
| CVE-2017-7974 | 1 Schneider-electric | 1 U.motion Builder | 2025-04-20 | N/A |
| A path traversal information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can execute arbitrary code and exfiltrate files. | ||||
| CVE-2017-5155 | 1 Schneider-electric | 1 Wonderware Historian | 2025-04-20 | N/A |
| An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. | ||||